Skip to content

Humidity Indicator Plugs – 18 – Supplied with Multi RH Card – Threaded Bosses

Price :

Humidity Indicator Plugs Supplied With Threaded Bosses

Cobalt Dichloride Free Humidity Indicator Cards offer the electronics and semiconductor industries a Cobalt Dichloride (CoCl2) Free humidity indicator (HI) card, while maintaining the accuracy required by international JEDEC standards.

What are they?

Cobalt Dichloride Free Humidity Indicator Cards provide electronic and semiconductor manufacturers with a JEDEC-compliant humidity indicator card that is free of Cobalt Dichloride, a chemical regulated under European Chemical Bureau (ECB) REACH directives.

Humidity Indicator Plugs Supplied With Threaded Bosses

Purpose
Humidity indicator plugs are designed to indicate the relative humidity level within a sealed container without users having to open it. Desiccator plugs both indicate and control humidity levels within the container.

What are they?
Humidity indicator plugs work much like humidity indicator cards but can be screwed into the outside walls of sealed containers.  Made of aluminum, brass or stainless steel, they feature large, clear viewing windows for easy reading of humidity levels within the container. In the case of desiccator plugs, a desiccant tube extends from the indicator into the container to keep products dry.

Why use them?
Sensitive goods are often housed in containers that either should not or cannot be opened until use. By installing humidity indicator or desiccator plugs into the walls of these containers, users can ensure that goods are housed at safe humidity levels without exposing them to external elements while humidity levels are checked.

Available configurations
Humidity indicator and desiccator plugs are available in a variety of sizes and configurations, detecting anywhere from 5 to 95 percent relative humidity. Plugs are compatible with rigid-wall equipment and electrical housings, as well as most flexible barriers. Desiccator plugs are primarily designed for small containers, mechanical boxes or sealed instruments where space is limited.

Plugs are adaptable to virtually all applications for Method II packaging of Mil-Std-2073-1D Method 50 and AS26860 aerospace specifications. Compact plugs are designed to be leak-resistant and temperature-proof, and to withstand shock and vibration.

Meet European Chemical Bureau (ECB) REACH directives

Cobalt Dichloride Free Humidity Indicator Cards offer the electronics and semiconductor industries a Cobalt Dichloride (CoCl2) Free humidity indicator (HI) card, while maintaining the accuracy required by international JEDEC standards.

What are they?

Cobalt Dichloride Free Humidity Indicator Cards provide electronic and semiconductor manufacturers with a JEDEC compliant humidity indicator card that is free of Cobalt Dichloride, a chemical regulated under European Chemical Bureau (ECB) REACH directives.

Why use them?

Some companies have expressed the desire to begin using a Cobalt Dichloride Free humidity indicator card. The Humitector CDF provides verifiable color-change accuracy as required by JEDEC standard J-STD-033B, as well as exceeds applicable regulations administered by the ECB.

Available configurations

The Cobalt Dichloride humidity indicator card is available in the standard JEDEC required format indicating 5, 10 and 60% RH, a 6 spot 10-60% RH Card (similar to the AEC826004NE) and a 4 spot 10-40% RH Card (similar to the HM-04 HIC).

  • Key Points
    • Cobalt-Dichloride Free Hi Cards are free of Cobalt-Dichloride (CoCl2), a chemical which has classification and labeling requirements under the European Chemical Agency (ECHA) REACH directives
    • Fully compliant with JEDEC standard J-STD-033B for color-change accuracy
    • Meets all relevant ECB/REACH labeling requirements
    • Typical applications include the dry packaging of semiconductor and electronic devices

Cobalt Dichloride Free 5-10-15% Humdity Indicator

Specifications:

  • MFG#: 200014539 / 51015-CDF
  • Meets the requirements of Jedec J-STD-033
  • Shipping Wt.: 8 oz. per can
  • Packaged: 125 per pint can
  • Printing: Heavy Black on White
  • Indicating Spots: 5-10-15% RH
  • Material: Blotting Paper
  • Dimensions: 2″ x 3″

Cobalt Dichloride Free 5-10-60% Humdity Indicator

Specifications:

  • MFG#: 200014484 / 51060-CDF
  • Meets the requirements of Jedec J-STD-033
  • Shipping Wt.: 8 oz. per can
  • Packaged: 125 per pint can
  • Printing: Heavy Black on White
  • Indicating Spots: 5-10-60% RH
  • Material: Blotting Paper
  • Dimensions: 2″ x 3″

Cobalt Dichloride Free 6 Spot, AEC826004NE

Specifications:

  • MFG#: 200014540 / AEC826004NE-CDF
  • Shipping Wt.: 15 oz. per can
  • Packaged: 200 per pint can
  • Printing: Heavy Black on White
  • Indicating Spots: 10 through 60% RH
  • Material: Blotting Paper
  • Dimensions: 2″ x 4.75 “

Cobalt Dichloride Free 4 Spot Humidity Indicator Card

Specifications:

  • MFG#:200014541 / HM04-CDF
  • Shipping Wt.: 7 oz. per can
  • Packaged: 125 per pint can
  • Printing: Heavy Black on White
  • Indicating Spots:10 through 40% RH
  • Material: Blotting Paper
  • Dimensions: 2″ x 3″

Do you have a Question or Concern?

"*" indicates required fields

Name*
This field is for validation purposes and should be left unchanged.